Radiation Safety for Operators and Patients
Cathing for Two: Pregnancy in the Cath Lab
Cathing for Two: Pregnancy in the Cath Lab
Back to course
[Please upgrade your browser to play this video content]
Video Transcription
Video Summary
The speaker, an interventional cardiologist, discusses radiation safety for pregnant staff and patients in the cath lab. Key points include ALARA principles, continuous dosimetry, lower frame rates, shorter fluoroscopy time, and using shielding and newer protective devices. Pregnant workers have legal rights to accommodations, monitoring, and a safe environment, with recommended exposure limits of 0.5 mSv per month and 5 mSv for pregnancy. Studies suggest pregnancy in the cath lab can be managed safely with proper precautions. For pregnant patients, a multidisciplinary approach, fetal monitoring, left lateral tilt, and emergency preparedness are emphasized.
Asset Subtitle
Arasi Maran, MD, FSCAI
Keywords
radiation safety
pregnant staff
cath lab
ALARA principles
fetal monitoring
×